Buyer GuideOctober 25, 2026 · 18 min read · VEMERIX

Cannula or Needle for Filler Delivery: Sizing, Evidence and Supplier Checks

Compare dermal filler cannula and needle quotations by dimensions, pilot pairings, comparative safety evidence and regulatory files before approving manual delivery stock.

Aesthetic DeliveryInjection ConsumablesSupplier QualificationProcurement & RFQ
Buyer Guide illustration detailing dermal filler cannula and needle selection, gauge and pilot pairing, regulatory evidence and RFQ checks.

A distributor receives a quotation for sterile single-use microcannulas. The cover letter promises that the cannulas “eliminate vascular risk”, attaches a single certificate and lists “pilot needle included” without a gauge or length. A clinic group the distributor supplies already stocks sharp needles and asks whether adding cannula kits is worth the extra line items. Which configuration fields, evidence layers and regulatory documents must be resolved before either line is approved for the filler portfolio?

This guide treats that as a stock-qualification question, not a clinical one. Which instrument suits a given patient, region or product is decided by a qualified practitioner working within the filler's and the hardware's instructions for use (IFU). FDA notes that approved fillers are supplied for injection using a syringe with a needle or cannula, and that approved indications vary by product.2

Useful buyer-facing guidance already exists. Derma Fill Supply's procurement framework, for example, covers wall classes, pack sizes, sterile-barrier expiry and residual risk.15 This guide adds source-linked reconciliation: actual kit contents from two dated catalogs, worked official records for both the hardware and the filler, a ledger of what each study measured, and a line-item worksheet that ends in an explicit release or hold. For ISO 7864 dimensions and acceptance testing on the sharp-needle side, use our sterile hypodermic needle ISO 7864 specification and acceptance guide.

What exactly is in the cannula, pilot-needle or needle pack?

Sharp needles and blunt cannulas are bought differently. A blunt cannula enters through an opening made by a separate sharp needle, so cannula catalogs describe a pilot (introducer) needle alongside the cannula. Air-Tite says a pilot is included in each box of its listed STERiGLIDE sizes; DermaSculpt says its 30G/27G, 25G and 22G cannulas “come packaged with” a specified sharp needle.7, 8

Pack configuration is not uniform. Derma Fill Supply describes cannulas sold singly, in blisters of five, ten or twenty, and sometimes as a kit with the matched pilot included. It also notes that a larger pack saves money only if the stock is used before the sterile barrier's expiry date.15 An RFQ that says only “cannula 25G” therefore leaves at least three cost and workflow variables open: units per pack, whether a pilot is included, and whether each unit has its own sterile barrier.

For every quoted reference, ask for the label artwork or pack drawing showing the number of cannulas and pilots in each primary sterile pack, the sterile-barrier format, the labeled sterilization method, the shelf life and the units per carton. Seal-strength, package-integrity and aging evidence belongs in the supplier's packaging validation file; ask for its summary rather than inferring it from a catalog photograph.

Which configuration fields must the supplier confirm?

Gauge fixes the outer diameter only. The inner diameter depends on the wall class the manufacturer declares (regular, thin, extra-thin or ultra-thin), so two 25G instruments can differ in bore and in extrusion force, and extrusion force rises steeply as the bore narrows.15 Air-Tite's needle guidance makes the same point for needles: thin- and ultra-thin-wall needles have larger inner diameters than regular-wall needles.7 Neither cannula catalog reviewed here states a wall class for its cannulas, so request the declared wall designation and nominal inner diameter for every quoted cannula and pilot.

Lengths need the same care. Both catalogs sell a 1½-inch cannula, but Air-Tite labels it 38 mm and DermaSculpt labels it 40 mm.7, 8 Record the metric length exactly as it appears on the actual label, not a converted or rounded catalog value.

Table 1 reconciles the two catalogs as published on 25 October 2026. It compares documented kit contents only. It is not a compatibility test, a ranking, or a recommendation of any size for any indication.

Cannula gaugeAir-Tite STERiGLIDE: lengths and pilotDermaSculpt: lengths and pilotConfirm before ordering
22G38, 50 and 70 mm; 21G × 1″ pilot72″ (50 mm) and 2¾″ (70 mm); 21G pilot, length not stated8DermaSculpt pilot length; wall class and inner diameter (stated by neither page)
23GNot in the sizing table71⅛″ (30 mm) and 2″ (50 mm); pilot not stated8Whether a pilot is included, and its gauge. Derma Fill Supply's example pairs a 22G pilot with a 23G cannula15
24GNot in the sizing table71½″ (40 mm); pilot not stated8Whether a pilot is included, and its gauge
25G38 and 50 mm; 23G × ¾″ pilot71½″ (40 mm) and 2″ (50 mm); 23G pilot838 mm vs 40 mm label for the same nominal 1½″. Derma Fill Supply's example uses a 24G pilot15
27G25, 38 and 50 mm; 25G × ½″ pilot71″ (25 mm), 1½″ (40 mm) and 2″ (50 mm); 26G pilot8Pilot gauge differs by vendor (25G vs 26G); confirm pilot length
30G25 mm; 27G × ½″ pilot71″ (25 mm); 26G pilot8Pilot gauge differs by vendor (27G vs 26G); confirm pilot length
Table 1. Listed cannula lengths and included pilot needles in two vendor catalogs

Source: Air-Tite Aesthetics sizing guide (s7), DermaSculpt product site (s8) and the Derma Fill Supply framework (s15), all accessed 25 October 2026. Catalog pages change without notice and are not IFUs; confirm against current labeling before ordering.

Three suppliers, three conventions. Air-Tite describes the introducer as typically one to three gauges larger than the cannula, DermaSculpt says its gauge should be “slightly superior” to the cannula's, and Derma Fill Supply suggests one gauge larger.7, 8, 15 Each convention may suit its own kit, but none is a cross-brand rule. Approve the pilot that the quoted SKU's labeling and IFU specify, and do not substitute a loose needle from another line without the supplier's written confirmation.

Two further fields are often missing from quotations. The first is the hub connector. FDA's classification record for hypodermic needles lists ISO 80369-7, the small-bore connector standard for intravascular or hypodermic applications, among its recognized consensus standards.11 Ask which connector standard each needle and cannula hub claims, and whether it is Luer-lock or slip. The second is the tip and port. The GMDN term attached to one FDA device record describes a tissue injection cannula as typically having a closed nose and a lateral hole at the distal tip.10 Ask for a drawing showing tip form, port position and any orientation marking, rather than accepting “blunt tip” as a specification.

What does the comparative evidence actually measure?

Suppliers often present cannulas as categorically safer. One of the catalog pages in Table 1, for example, lists “No intravascular injection” and “Eliminating the risk of” necrosis and blindness among its cannula's features.8 A buyer who approves product claims for a portfolio should check what the published studies actually measured.

The most cited comparison is Alam et al.'s retrospective cohort study in JAMA Dermatology. A random sample of 370 board-certified dermatologists reported about 1.7 million syringes injected, with data collected from August 2018 to August 2019. Observed occlusion was 1 per 6,410 1-mL syringe injections with needles and 1 per 40,882 with cannulas. In a multivariate logistic regression that also included filler type, years in practice and weekly injection volume, cannula use was associated with 77.1% lower odds of occlusion. The authors also reported that the risk was very low with either instrument and that 85% of occlusions had no long-term sequelae.3

That is a real association, not a marketing invention, but it is not a “77% risk reduction” per patient. The authors state that data collection was not audited, that answers may rest on recall or estimation, that weekly figures were extrapolated, and that events reported by the same dermatologist are not statistically independent. They also state that the results do not generalize to other specialties or to non-physician injectors, and they conclude that the right instrument may depend on patient factors, anatomic site and the defect being treated.3

Mechanical evidence draws a sharper boundary. In Pavicic et al.'s cadaver study, 294 penetration procedures were performed on facial and superficial temporal arteries in four specimens. 22G and 25G cannulas needed more force to penetrate than needles of the same gauge, but at 27G there was no significant difference between cannula and needle (0.78 ± 0.35 N vs 0.70 ± 0.29 N; p = 0.558). The authors concluded that 27G cannulas are not safer than 27G needles on that measure.5 Penetration force in cadaver tissue is a mechanical endpoint and does not establish clinical event rates.

Source and designSampleEndpointReported findingLimit for a buyer's claim
Alam et al., 2021 (online December 2020): retrospective cohort370 dermatologists; ~1.7 million syringes; self-reported, unauditedOcclusion events per 1-mL syringe1 per 6,410 (needle) vs 1 per 40,882 (cannula); 77.1% lower adjusted odds with cannula3Association per syringe, not causal and not a patient-level risk; limited generalizability3
Pavicic et al., 2019: cadaver experiment4 specimens; 294 penetrations; needles 20–27G, cannulas 22–27GForce to penetrate the arterial wall22G/25G cannulas needed more force than same-gauge needles; no significant difference at 27G5Mechanical endpoint; supports gauge-specific caution, not a clinical rate5
Margolis et al., 2024: case reportSingle case reportReported adverse eventTitle reports vascular occlusion due to a blunt-tipped cannula4Shows that such an event can occur; gives no rate4
Hexsel et al., 2012: randomized, double-blind phase II trial25 participants; one nasolabial fold per instrumentWrinkle score and participant-reported side effects on injection daySimilar wrinkle-score improvement; fewer reports of pain, edema, redness and hematoma on the cannula side14Small, single region, short-term; not designed to detect rare vascular events14
Lee et al., 2025: narrative reviewSynthesis of trial, observational, cadaveric and consensus literatureComplication profiles and use casesCannulas associated with less bruising and a reduced occlusion signal, but not risk-free1Secondary synthesis; the authors note publication bias and heterogeneous endpoints1
Table 2. Evidence ledger: what each source measured, and its limits for a procurement claim

Source: Original publications (s3, s4, s5, s14) and one narrative review (s1). Quantitative findings are as reported by the authors; none was recomputed. The case report was reviewed at bibliographic-record level only.

Read together, these sources support a bounded statement. In the studies reviewed, cannulas were associated with fewer local side effects and fewer reported occlusions per syringe, and 22G and 25G cannulas resisted arterial penetration better than same-gauge needles. But occlusion due to a blunt cannula has been reported, and 27G cannulas showed no force advantage.3, 4, 5, 14 Lee et al. reach a similar position: cannulas are not inherently risk-free, and device choice should be individualized to region, indication and operator skill.1 For a buyer, that means rejecting absolute safety claims in supplier literature and leaving instrument choice to clinicians.

Does this hardware need a 510(k), or is an exemption applicable?

In the US, the two instruments usually fall under different product codes. FDA's FMI record (hypodermic single lumen needle, 21 CFR 880.5570) lists Class II with a 510(k) submission route.11 The GEA record (cannula, surgical, general and plastic surgery, under 21 CFR 878.4800, “manual surgical instrument for general use”) lists Class I and 510(k) exempt. FDA notes on that record that exempt status and any limitations, set out in the corresponding “.9” section, must be confirmed, and that exempt manufacturers must still register their establishment.9

That leads to two opposite mistakes. A buyer may reject a properly exempt cannula because the supplier has no K number. Or a buyer may accept “exempt” at face value for hardware whose intended use or design falls outside the generic category, which is exactly what the exemption limitations address.9 The supplier should state the product code and explain why the quoted device fits it. The buyer's job is to check that the explanation matches the label and IFU.

A worked example shows what a public record can and cannot settle. The AccessGUDID entry for Dermasculpt device identifier 10652927775935 (public version dated 22 March 2024) names Demetech Corporation as labeler and records model DS23G50, product code GEA, “Device Exempt from Premarket Submission: Yes” and “Device Packaged as Sterile: Yes”, under the GMDN term “Tissue injection cannula”. The same record lists no device size and no sterilization method.10 It supports a code and exemption claim for that identifier. It does not confirm gauge, length, pilot contents, sterilization method or the identity of a quoted lot, and the labeler it names is not the company name shown on the catalog page.8, 10 GUDID entries are submitted by labelers; they are not an FDA approval.

When a quoted needle claims a 510(k) clearance, follow our walkthrough on how to verify an FDA 510(k) clearance and match the applicant, device name and product code to the quoted item.

How does the filler approval differ from the hardware record?

The filler and the hardware have separate regulatory files. FDA approves dermal fillers as medical devices, and the PMA database records each approval and supplement.2, 12 The agency notes that approved indications vary by product and that it may not have reviewed use of some fillers in certain locations of the body.2

PMA supplement P040024/S101 illustrates the boundary. FDA's record, with a decision date of 2 November 2018, approved “the use of a small bore, blunt tip cannula with Restylane Lyft with Lidocaine for cheek augmentation and the correction of age related midface contour deficiencies in patients over the age of 21”. The applicant was Q-Med AB, the product code is LMH (implant, dermal, for aesthetic use), and the supplement is recorded as a labeling change.12 Galderma's 5 November 2018 announcement describes the same event and a supporting 60-subject open-label study; it is not a separate authorization.13

That approval changed what the filler's labeling allows. It did not clear or approve any independent cannula line, and the approval statement names no gauge or cannula brand.12 Treat supplier phrases such as “FDA approved for [filler brand]” as claims to verify: ask which regulatory record supports them, and compare them with the filler's current IFU. Because FDA describes approved fillers as supplied for injection with a syringe and needle or cannula, check what the filler's own pack and IFU specify before assuming that separately bought hardware is interchangeable.2

Which EU classification and conformity documents match the intended use?

In the EU, classification follows Annex VIII of Regulation (EU) 2017/745. MDCG 2021-24 Rev.1 (April 2026) explains that Rule 6 covers devices used to create a conduit through the skin, such as needles and cannulae, and places transient surgically invasive devices in Class IIa unless an exception applies. Examples are reusable surgical instruments (Class I) and devices specifically intended to control, diagnose, monitor or correct a defect of the heart or central circulatory system (Class III). The guidance states that it is not legally binding.6

For ordinary single-use filler cannulas and needles, Rule 6 Class IIa is therefore the starting point for screening, not a conclusion; the manufacturer's intended purpose and any other applicable rule decide. MDCG also notes that notified-body involvement in conformity assessment increases with device class, with the procedures set out in MDR Annexes IX to XI.6 Ask the supplier for its classification rationale, the EU declaration of conformity and the notified-body certificate it relies on. Then ask how each quoted reference traces to those documents, for example through Basic UDI-DI or catalog references, since individual sizes need not be printed on the face of a certificate. Our guide on how to verify a CE certificate and notified body covers NANDO and certificate-scope checks.

ItemRecord or ruleEstablishesDoes not establishBuyer check
US blunt cannulaGEA: Class I, 510(k) exempt, 21 CFR 878.4800; exemption limitations apply9The generic category is exempt from premarket notificationThat a specific device's intended use fits the categorySupplier's product-code rationale; establishment registration; UDI record matching the label9, 10
US hypodermic needleFMI: Class II, 510(k), 21 CFR 880.557011A 510(k) route appliesClearance of any particular needleK number matching applicant, device and product code
US dermal fillerPMA (product code LMH), e.g. supplement P040024/S10112What the filler's labeling allowsClearance or approval of third-party cannulasCurrent filler IFU compared with the hardware labeling
EU cannula or needleMDR Annex VIII Rule 6; MDCG 2021-24 Rev.16Class IIa as the default for transient surgically invasive devicesA product-specific classification, or certificate coverage of each SKUClassification rationale; declaration of conformity; notified-body certificate; traceability of each reference
UDI recordAccessGUDID device identifier entry, submitted by the labeler10Labeler, model, product code and exemption flag for that identifierDimensions (none listed in the example), lot identity or any approvalMatch the identifier on the physical label to the record
Table 3. What each regulatory record establishes, and what it does not

Source: FDA classification records GEA (s9) and FMI (s11), AccessGUDID (s10), PMA supplement P040024/S101 (s12) and MDCG 2021-24 Rev.1 (s6), checked 25 October 2026.

Which supplier records and receiving checks justify releasing stock?

Evidence requests should follow the hardware's actual regulatory route rather than a fixed test list. FDA's 510(k) sterility guidance (January 2024) recommends that submissions for devices labeled sterile state a sterility assurance level (SAL) of 10−6 unless the device contacts only intact skin. It also says devices in direct or indirect contact with the cardiovascular or lymphatic system, among others, should meet pyrogen limit specifications, with a recommended limit of 20 endotoxin units per device for general medical devices.17 These are recommendations for 510(k) submissions, so they do not automatically apply to an exempt cannula. They still give a reasonable structure for what to ask any sterile-hardware supplier: the sterilization method and site, the validation basis, the declared SAL, and whether and on what basis the device is labeled non-pyrogenic.

Biological safety works the same way. FDA's guidance on ISO 10993-1 describes biological evaluation within a risk-management process, in which the need for testing depends on the device's nature and duration of body contact.18 Ask for the biological evaluation plan or report covering the quoted materials and configuration, rather than prescribing a test list or accepting one generic test report.

At receipt, checks should confirm that what arrived is what was qualified: sterile barriers are intact; the reference, lot, expiry date and UDI on the label match the order and the approved worksheet; the pilot gauge and count printed on the pack match the approved configuration; and the IFU is present at the expected revision. Qualified QA staff should set sample sizes and any dimensional or destructive checks under a documented plan; our guide to an incoming AQL sampling plan for sterile consumables covers that method. This guide deliberately proposes no acceptance limits.

How should the RFQ record unresolved evidence and disposition?

The worksheet below turns those questions into one row per field, to be completed for each quoted reference. It is an editorial procurement tool, not a regulatory checklist or a validated test protocol; adapt it with your QA and regulatory staff.

FieldWhat to recordEvidence that settles itHold the line if…
Supplier and referenceLegal manufacturer, labeler, seller, catalog number, UDI-DILabel artwork; UDI record10Manufacturer, labeler and seller cannot be reconciled
Instrument and gaugeCannula or needle; gauge; declared wall class; nominal inner diameterDrawing or specification sheet15Wall class or bore is described only as “standard”, or is undeclared
Labeled lengthMetric length exactly as labeledLabel artwork7, 8Quoted and labeled lengths differ
Tip, port and hubTip form; port position; claimed connector standard; Luer-lock or slipDrawing; connector-standard declaration11Tip described only as “blunt”, or connector undeclared
Pilot needleIncluded or not; gauge; length; count per packPack drawing; IFU7, 8“Pilot included” with no gauge or length
Pack configurationUnits per sterile pack and per carton; barrier format; shelf lifePack drawing; packaging validation summary15Pack contents or shelf life not documented for the quoted reference
US routeProduct code; 510(k) number or exemption basisClassification and UDI records; 510(k) database9, 11Exemption asserted without a product-code rationale, or a K number that does not match
EU routeClass and rule; declaration of conformity; notified-body certificate; reference traceabilityClassification rationale; declaration; certificate6Quoted references cannot be traced to the declaration of conformity
Sterility and pyrogenicityMethod; site; validation basis; SAL; non-pyrogenic claimSterilization validation summary17Sterile claim without a method or validation reference
Biological evaluationPlan or report covering the quoted materials and configurationBiological evaluation report18Generic report not tied to the quoted materials
Filler and IFU scopeFillers the clinic intends to use; what each filler's IFU specifiesCurrent filler IFU; PMA record where relevant2, 12Supplier claims filler-specific approval it cannot document
Product claimsSafety or performance claims in supplier literatureEvidence for each claim, read by endpoint3, 5Absolute claims such as “no intravascular injection”
Owner and dispositionNamed owner; open questions; release, clarify or hold; dateSigned worksheetAny open question on a line proposed for release
Table 4. Line-item worksheet for each quoted cannula or needle reference

Source: VEMERIX editorial worksheet built from the sources cited in each row. It sets no sampling plan, test method or acceptance limit.

Applied to the opening scenario, the cannula quotation stays on hold: the pilot is unspecified, the claim that the cannulas “eliminate vascular risk” conflicts with the evidence in Table 2, and a single certificate does not show how each reference is covered. The existing sharp-needle line is not automatically cleared either; it still needs its own route, label and pack contents verified against the worksheet. The decision is made per configuration, not per instrument type.

Where VEMERIX fits—and where due diligence still begins

VEMERIX is the international brand of Weihai Medison Medical Equipment Co., Ltd., positioned as a Minimally Invasive Surgery Total Solution Platform serving urology, vascular surgery and perioperative care.

In aesthetic delivery, the VEMERIX portfolio includes a Sterile Single-Use Injection Needle. Its product page describes it as an NMPA Class III registered device for aesthetic and hydrofacial workflows that pairs with syringe-assist injector workflows. That page provides no filler-specific IFU, describes no blunt cannula, and states no US or EU market status for this needle.16 Nothing in this guide should be read as recommending it for filler delivery.

Where VEMERIX can help is the evidence step. A buyer evaluating sterile single-use injection consumables for distribution, private label or a defined aesthetic workflow can send the target market, the required configurations and the intended use through VEMERIX commercial enquiries, and request the registration and technical documents that apply. Due diligence then uses the same worksheet as for any other supplier.

Frequently asked questions

Can a blunt cannula still be associated with vascular occlusion?

Yes. A large retrospective cohort associated cannulas with lower odds of occlusion per syringe, but a published case report describes occlusion due to a blunt-tipped cannula, and a cadaver study found no significant difference in arterial penetration force between 27G cannulas and 27G needles.3, 4, 5 A recent narrative review likewise concludes that cannulas are not inherently risk-free.1

Does the same gauge mean the same inner diameter?

No. Gauge fixes the outer diameter; the inner diameter follows the declared wall class, so two instruments of the same gauge can differ in bore and extrusion force.15 Thin- and ultra-thin-wall needles have larger inner diameters than regular-wall needles.7 Ask for the declared wall class and nominal inner diameter in writing.

Is the pilot needle supplied, and must its size be identical across brands?

Often, but not always, and sizes differ. On 25 October 2026, Air-Tite listed a 25G pilot with its 27G cannulas while DermaSculpt listed a 26G pilot, and another supplier's guide suggested a pilot one gauge larger than the cannula.7, 8, 15 Record the pilot gauge, length and count specified for each quoted SKU.

Does absence of a K number always disqualify a cannula?

No. FDA lists GEA cannulas as Class I and 510(k) exempt, subject to the exemption limitations, while noting that exempt manufacturers must still register their establishment.9 Ask the supplier for its product-code rationale and check the UDI record against the physical label; one public record does not confirm dimensions or lot identity.10

Does filler approval authorize every delivery instrument?

No. A filler PMA supplement such as P040024/S101 defines what that filler's labeling allows, including use with a small-bore blunt-tip cannula for the stated indication; it names no cannula brand and does not clear independent cannula lines.12

Can this framework establish that a VEMERIX needle is suitable for a particular filler?

No. The public product page describes an NMPA Class III sterile single-use injection needle for aesthetic and hydrofacial workflows, with no filler-specific IFU.16 Suitability for any filler depends on that filler's IFU and on documents the buyer would need to request and review.2

Is a blunt cannula the same as a needle-free injector?

No. A cannula is a hollow tube attached to a syringe and introduced through an opening made by a sharp needle.7, 8 FDA states that needle-free devices are not approved for injecting dermal fillers, that their safety and effectiveness for that use is not known, and that it is aware of serious adverse events associated with them.2

Sources

  1. JPRAS Open — Lee KWA et al., "Cannula is safer than needle in filler injection?", narrative review; published 11 December 2025; 48:415–424.
  2. U.S. Food and Drug Administration — Dermal Fillers (Soft Tissue Fillers): information for patients and health care providers, including delivery with a needle or cannula, varying approved indications and the status of needle-free devices.
  3. JAMA Dermatology — Alam et al., "Rates of Vascular Occlusion Associated With Using Needles vs Cannulas for Filler Injection", retrospective cohort of 370 dermatologists and ~1.7 million syringes; 2021;157(2):174–180 (published online December 2020).
  4. JAAD Case Reports — Margolis et al., "Vascular occlusion due to blunt-tipped cannula: Case report and simplifying best practices", 2024;55:16–18 (online 4 November 2024; January 2025 issue); PubMed record.
  5. Plastic and Reconstructive Surgery — Pavicic et al., "Arterial Wall Penetration Forces in Needles versus Cannulas", cadaveric experiment (4 specimens, 294 penetration procedures); 2019;143(3):504e–512e.
  6. Medical Device Coordination Group — MDCG 2021-24 Rev.1, Guidance on classification of medical devices (April 2026), including Section 2.2 on conformity assessment and Annex VIII Rule 6; nonbinding guidance.
  7. Air-Tite Aesthetics — Microcannula and Needle Sizing Guide: STERiGLIDE cannula sizes and the pilot needle included in each box; accessed 25 October 2026.
  8. DermaSculpt (CosmoFrance) — DermaSculpt Microcannula product site: listed sizes, packaged sharp needles and product claims; accessed 25 October 2026.
  9. U.S. Food and Drug Administration — Product Classification: GEA, cannula, surgical, general & plastic surgery (21 CFR 878.4800; Class I; 510(k) exempt; exemption limitations apply).
  10. FDA/NLM AccessGUDID — Dermasculpt device identifier 10652927775935 (labeler Demetech Corporation; model DS23G50; product code GEA; premarket exempt; public version 22 March 2024).
  11. U.S. Food and Drug Administration — Product Classification: FMI, needle, hypodermic, single lumen (21 CFR 880.5570; Class II; 510(k)), including listed recognized consensus standards such as ISO 80369-7.
  12. U.S. Food and Drug Administration — PMA database, P040024/S101, Restylane Lyft with Lidocaine Cannula Injection (applicant Q-Med AB; product code LMH); decision date 2 November 2018.
  13. Galderma — Galderma Announces FDA Approval of Restylane Lyft for Midface Injection via Cannula, press release, 5 November 2018.
  14. Dermatologic Surgery — Hexsel et al., "Double-blind, randomized, controlled clinical trial to compare safety and efficacy of a metallic cannula with that of a standard needle for soft tissue augmentation of the nasolabial folds"; 2012;38(2):207–214.
  15. Derma Fill Supply procurement team — "Cannula or needle? A practical selection framework", commercial procurement editorial; 12 August 2026.
  16. VEMERIX — Sterile Single-Use Injection Needle product page (NMPA Class III registered device for aesthetic and hydrofacial workflows).
  17. U.S. Food and Drug Administration — Submission and Review of Sterility Information in Premarket Notification (510(k)) Submissions for Devices Labeled as Sterile, nonbinding guidance issued 8 January 2024.
  18. U.S. Food and Drug Administration — Use of International Standard ISO 10993-1, Biological evaluation of medical devices – Part 1: Evaluation and testing within a risk management process, final guidance (September 2023).

Talk to VEMERIX

VEMERIX is the international brand of Weihai Medison Medical Equipment Co., Ltd., positioned as a Minimally Invasive Surgery Total Solution Platform serving urology, vascular surgery and perioperative care.